Section 7

Refrigeration System

 

 

Section 7

Refrigeration System

Sequence of Operation

SELF-CONTAINED WATER -COOLED MODELS

EVAPORATOR

HEAT

EXCHANGER

EXPANSION VALVE

HOT GAS SOLENOID VALVE

X

COMPRESSOR

AIR OR WATER

STRAINERCONDENSER

DRIER

RECEIVER

(WATER COOLED ONLY)

HIGH PRESSURE VAPOR

HIGH PRESSURE LIQUID

LOW PRESSURE LIQUID

LOW PRESSURE VAPOR

 

 

 

SV1569

Figure 7-1. Self-Contained Prechill and Freeze Cycle

Prechill Refrigeration Sequence

No water flows over the evaporator during the prechill. The refrigerant absorbs heat (picked up during the harvest cycle) from the evaporator. The suction pressure decreases during the prechill.

Freeze Cycle Refrigeration Sequence

The refrigerant absorbs heat from water running over the evaporator surface. The suction pressure gradually drops as ice forms.