Electrical System | Section 6 |
|
|
Wiring Diagram Sequence of Operation
SELF-CONTAINED MODELS
Initial Start-Up or Start-Up After Automatic Shut-Off
1. WATER PURGE
Before the compressor starts, the water pump and water dump solenoid are energized for 45 seconds to purge old water from the ice machine. This ensures that the
The harvest valve(s) is also energized during the water purge. In the case of an initial refrigeration
5 seconds (50 seconds total).
The air compressor energizes for the last 10 seconds of the cycle.
L1 |
|
|
|
| L2 or N |
Ground |
|
|
| Water Valve |
|
|
|
|
|
| |
(89) | (55) | (20) | (21) | (99) | |
(61) |
| (22) | |||
High |
|
|
| ||
Control Board |
| Harvest Valve |
| ||
Pressure |
|
| |||
(2) |
| (77) |
|
| |
(88) Cutout | (6) | (60) |
| (80) |
|
|
|
| |||
| (5) |
| Dump Valve | (75) | |
| (1) |
|
|
|
|
| (7) |
| (76) | (81) |
|
| (4) | (57) | Water Pump |
| |
|
| (98) |
|
| |
|
|
|
|
| |
(42) | Trans. | (58) |
|
|
|
| Fuse (7a) |
| Terminates at |
| |
|
|
|
| ||
|
|
| (59) | Pin Connection |
|
|
|
|
|
| |
|
| L2 | Contactor Coil |
|
(25)(56)
|
|
| (26) | Air Compressor |
|
|
|
| |
Ice Thickness | (9) |
|
| (74) |
Probe | (8) |
| ||
Water Level Probe |
|
| Bin Switch | |
Low DC |
| (6) |
| |
|
|
| ||
| Voltage |
| (1) | Clean |
| Plug |
| ||
|
|
|
| OFF |
|
|
|
| ICE |
|
| (Red) | (2) |
|
|
| Compressor |
|
|
Contactor | Overload | (Yellow) | (46) | Run Capacitor |
|
| (50) | ||
Contacts | (Black) |
|
| |
L1 |
|
| (45) | |
|
|
|
(51) | (85) | (86) | PTCR |
|
Fan Motor
Fan Cycle
Control
Run Capacitor
|
|
| |
Table |
|
| |
|
|
|
|
|
| 1. Water Purge (45 Seconds) | |
Toggle Switch |
| ICE | |
Bin Switch |
| Closed | |
Control Board Relays |
|
| |
#1 | Water Pump |
| ON |
#2 | Harvest Valve (Left) |
| ON |
#3 | Harvest Valve (Right) |
| ON (When Used) |
#4 | Air Compressor |
| 35 sec. OFF / 10 sec. ON |
#5 | Water Inlet Valve |
| OFF |
#6 | Water Dump Valve |
| ON |
#7 | Contactor Coil |
| Open / OFF |
#7A | Compressor |
| OFF |
#7B | Condenser Fan Motor |
| OFF |
Safety Controls (Which could stop ice machine operation) |
| ||
| High Pressure |
| Closed |
| Main Fuse (On Control Board) |
| Closed |
Part Number |