4. FREEZE
The water pump starts after the pre- chill. An even flow of water is directed across the evaporator and into each cube cell, where it freezes.
The water fill valve will cycle off then on one more time to refill the water trough.
When sufficient ice has formed, the water flow (not the ice) contacts the ice thickness probes. After approximately 10 seconds of continual contact, a harvest cycle is initiated.
NOTE: The ice machine cannot initiate a harvest cycle until a 6- minute freeze lock has expired.
L1 |
|
|
| L2 or N |
Ground |
|
| Water Valve | (99) |
|
|
| ||
|
| (20) | (21) | |
(89) | (55) |
| ||
(61) | (22) |
| ||
High |
|
| ||
Control Board |
| Harvest Valve |
| |
Pressure |
|
| ||
(2) |
|
| ||
(88) Cutout | (60) | (77) |
| |
(6) |
| |||
| (80) |
| ||
| (5) |
| Dump Valve | (75) |
| (1) |
| (76) | |
| (7) |
| (81) |
|
| (4) | (57) | Water Pump |
|
|
| (98) |
| |
|
|
|
| |
(42) | Trans. | (58) |
|
|
| Fuse (7a) | Terminates at |
| |
|
|
| ||
|
|
| Pin Connection |
|
|
|
|
|
|
| (59) |
|
|
| L2 |
|
| Contactor Coil |
|
|
| (25) |
|
| (56) |
|
|
|
| (26) |
| Air Compressor |
|
|
|
|
|
| |
Ice Thickness |
| (9) |
|
|
| (74) |
Probe |
| (8) |
|
| ||
Water Level Probe |
|
|
|
| Bin Switch | |
| Low DC |
| (6) |
| ||
|
|
|
| |||
|
| Voltage |
|
|
| Clean |
|
| Plug |
| (1) |
| |
|
|
|
| OFF | ||
|
|
|
|
| ||
|
|
|
| (2) |
| ICE |
|
| (Red) |
|
|
| |
|
|
|
|
|
| |
|
| Compressor |
|
| Run Capacitor | |
Contactor | Overload | (Yellow) |
| (46) | ||
|
| |||||
|
|
|
| (50) | ||
Contacts |
|
|
|
|
| |
(Black) |
|
|
|
|
| (45) |
L1 |
|
|
|
|
| |
(51) | (85) | (86) |
|
| PTCR | |
| Fan Motor | |||||
| Fan Cycle |
| ||||
|
|
|
|
| ||
| Control |
|
|
|
|
Run Capacitor | |
|
Self-Contained — Freeze
Table 6-4. Self-Contained Models
4.Freeze (Until 10 Seconds of Water Contact with Ice Thickness Probe)
Toggle Switch
Bin Switch
Control Board Relays
ICE
Closed
#1 | Water Pump | ON | |
#2 | Harvest Valve (Left) | OFF | |
#3 | Harvest Valve (Right) | OFF (When Used) | |
#4 | Air Compressor | OFF (When Used) | |
#5 | Water Inlet Valve | Cycles OFF, then ON | |
one more time | |||
|
| ||
#6 | Water Dump Valve | OFF | |
#7 | Contactor Coil | Closed / ON | |
#7A | Compressor | ON | |
#7B | Condenser Fan Motor | May Cycle ON / OFF | |
Safety Controls (Which could stop ice machine operation) |
| ||
| High Pressure | Closed | |
| Main Fuse (On Control Board) | Closed |