Section 6 | Electrical System |
|
|
DIAGNOSING WATER LEVEL CONTROL CIRCUITRY
Problem: Water Trough Overfilling During The
Freeze Cycle
Step 1 Start a new freeze sequence by moving the ICE/ OFF/CLEAN toggle switch to OFF, then back to ICE. (if water flows with the switch off, check the water inlet valve).
Step 2 Wait until the freeze cycle starts
(the freeze cycle starts when the water pump energizes).
Step 3 Disconnect water level probe wire from control board and connect a jumper from the control board terminal and any cabinet ground, then refer to chart.
Important
This restart must be done prior to performing diagnostic procedures. This assures the ice machine is not in a freeze cycle water inlet valve safety shut off mode. You must complete the entire diagnostic procedure within 6 minutes of starting.
Important
For the test to work properly you must wait until the freeze cycle starts, prior to connecting the jumper wire. If you restart the test you must disconnect the jumper wire, restart the ice machine, (step 1) and then reinstall the jumper wire after the compressor starts.
GREEN WATER LEVEL LIGHT
WATER LEVEL PROBE CONNECTION
SV3135
Step 3
Step 3 Jumper wire connected from control board terminal to ground
Is water flowing into | The Water Level | The Water Inlet Valve | Cause | |
the water trough? | Light is: | Solenoid Coil is: | ||
| ||||
NO | ON | The water level probe is causing the problem. | ||
Clean or replace the water level probe. | ||||
|
|
| ||
YES | ON | Energized | The control board is causing the problem. | |
YES | OFF | The water fill valve is causing the problem. |