Manitowoc Ice S1800 service manual Water Trough, Water Distribution Tube Removal

Models: S1800

1 100
Download 100 pages 24.15 Kb
Page 31
Image 31

Section 4

Maintenance

 

 

3. Water Distribution Tube

!Warning

Removing the distribution tube while the water pump is running will allow water to spray from ice machine. Disconnect the electrical power to the ice machine and dispenser at the electric service switch box and turn off the water supply.

NOTE: Distribution tube thumbscrews are retained by o- rings to prevent loss. Loosen thumbscrews but do not pull thumbscrews out of distribution tube.

A

B

4.Water Trough

A.Depress tabs on right and left side of the water trough.

B.Allow front of water trough to drop as you pull forward to disengage the rear pins.

DEPRESS TABS

Water Distribution Tube Removal

A.Remove outer half of distribution tube by loosening the four (4) thumbscrews (o-rings retain thumbscrews to distribution tube).

B.Pull inner half of water distribution tube forward to release slip joint from water pump tubing connection.

Part Number 80-1634-3