Marantz SR5005 Resetting the microprocessor, Auto, SURR. o p ENTER MODE, On/Standby, Menu Band

Models: SR5005

1 91
Download 91 pages 34.03 Kb
Page 85
Image 85
Resetting the microprocessor

ENGLISH

GiPodH

Symptom

Cause/Solution

Page

 

 

 

iPod cannot be

• Check the iPod connections.

19

played.

• Switch the input source to “USB”.

22

 

• Incompatible iPod types cannot be played back.

19

“Connection Error”

• Unable to communicate properly. Turn off the power to this unit,

is displayed.

disconnect the iPod and then reconnect it.

 

“Not Support” is

• The iPod connected to the unit is not compatible. Please make

19

displayed.

sure the iPod you are connecting is compatible.

 

 

• The software version of the connected iPod is an old one. Please

 

update to the latest version.

 

“Connection Error”

• The iPod is not responding. Turn off the power to this unit,

is displayed.

disconnect the iPod and then reconnect it.

 

When an iPod is

• “No Connection” may display if you connect an iPod that has

connected, “No

only a small amount of charge remaining in its battery to this unit.

 

Connection” is

Should this occur, charge the iPod before connecting it to this unit.

 

displayed.

 

 

GM-XPortH

 

 

Symptom

Cause/Solution

Page

 

 

 

Audio is not output

• Check that the Bluetooth device and Wireless receiver (RX101)

when a wireless

are correctly paired.

 

receiver (RX101 is

 

 

connected).

 

 

GRemote control unitH

 

 

Symptom

Cause/Solution

Page

Resetting the microprocessor

Perform this procedure if the display is abnormal or if operations cannot be performed. When the microprocessor is reset, all the settings are reset to their default values.

Various setting details can be saved and reset on this device. If setting details are saved before returning to the default values, after returning to the default settings, setting details can be returned to the same values as before returning to the defaults.

To return all of the settings to the default values, perform steps 2 to 4 without performing step 1.

ON/STANDBY

AUTO

MENU BAND

SURR. o p ENTER

MODE

1 When the power is ON, press and hold BAND and ENTER for more than 3 seconds. After “MEMORY SAVING” is shown on the display, “COMPLETE”is shown to inform you that the settings have been saved.

The set cannot be operated with the remote control unit.

Batteries are worn out. Replace with new batteries.

Operate the remote control unit within a distance of about 23 ft/7 m from this unit and at an angle of within 30°.

Remove any obstacle between this unit and the remote control unit.

Insert the batteries in the proper direction, checking the q and w marks.

The set’s remote control sensor is exposed to strong light (direct sunlight, inverter type fluorescent bulb light, etc.). Move the set to a place in which the remote control sensor will not be exposed to strong light.

72

72

72

72

72

2 Turn off the power using ON/STANDBY.

3 Press ON/STANDBY while simultaneously pressing SURR. MODE and AUTO.

4 Once the display starts flashing at intervals of about 1 second, release the two buttons.

5 Press and hold MENU and BAND for more than 3 seconds.

After “MEMORY LOAD” is shown on the display, “COMPLETE” is shown to inform you that the settings have returned to those saved in step 1.

If in step 4 the display does not flash at intervals of about 1 second, start over from step 2.

82

Page 85
Image 85
Marantz SR5005 manual Resetting the microprocessor, Auto, SURR. o p ENTER MODE, On/Standby, Menu Band, English