MicroNet Technology SP1659P Simple Counter, y Flow Control, y State, y Speed / Duplex, Media type

Models: SP1659P

1 123
Download 123 pages 31.25 Kb
Page 20
Image 20
Media type

Parameter description:

yState:

Set the communication capability of the port is enabled or disabled. When enabled, traffic can be transmitted and received via this port. When disabled, the port is blocked and no traffic can be transferred through this port. Port State is configurable by the user. There are only two states “Enable” and “Disable” able to choose. If you set a port’s state “Disable”, then that port is prohibited to pass any traffic, even it looks Link up.

Default: Enable.

ySpeed / Duplex:

Set the speed and duplex of the port. In speed, 10/100Mbps baud rate is available for Fast Ethernet, Gigabit module in port 25, 26. If the media is 1Gbps fiber, it is always 1000Mbps and the duplex is full only. If the media is TP, the Speed/Duplex is comprised of the combination of speed mode, 10/100/1000Mbps, and duplex mode, full duplex and half duplex. The following table summarized the function the media supports.

Media type

100M TP

1000M TP

1000M Fiber

 

NWay

 

Speed

 

Duplex

 

 

ON/OFF

 

10/100M

 

Full/Half

 

 

 

 

 

 

 

ON/OFF

 

10/100/1000M

 

Full for all, Half for 10/100

 

 

 

 

 

 

 

ON/OFF

 

1000M

 

Full

 

 

 

 

 

 

 

In Auto-negotiation mode, no default value. In Forced mode, default value depends on your setting.

yFlow Control:

There are two modes to choose in flow control, including Symmetric and Asymmetric. If flow control is set Symmetric, both parties can send PAUSE frame to the transmitting device(s) if the receiving port is too busy to handle. When it is set Asymmetric, this will let the receiving port care the PAUSE frame from transmitting device(s), but it doesn’t send PAUSE frame. This is one-way flow control.

Default: Symmetric.

3.4.3 Simple Counter

The function of Simple Counter collects any information and provides the counting about the traffic of the port, no matter the packet is good or bad. As below, the window can show all ports’ counter information at the same time. Each data field has 12-digit long. If the counting is overflow, the counter will be reset and restart counting. The data is updated every time interval defined by the user. The valid range is 3 to 10 seconds. The Refresh

19

Page 20
Image 20
MicroNet Technology SP1659P user manual Simple Counter, y Flow Control, y State, y Speed / Duplex, Media type, NWay