Data bit:

8

Stop bit:

1

Flow control:

None

Press “Enter” key to begin login screen. Enter the username and password to login the management console.

To see the commands of the mode, please input “?” after the prompt, then all commands will be listed in the screen. All commands can be divided into two categories, including global commands and local commands. Global commands can be used wherever the mode you are. They are “exit”, “end”, “help”, “history”, “logout”, “save start”, “save user”, “restore default” and “restore user”.

Command instructions reside in the corresponding modes are local commands. The same command with the same command name may occur but perform totally different function in different modes. For example, “show” in IP mode performs displaying the IP information; however, it performs displaying the system information in system mode.

4.2 Global Command

4.2.1 end

Syntax: end

Description: Back to the top mode.

When you enter this command, your current position would move to the top mode. If you use this command in the top mode, you are still in the position of the top mode.

Argument: None.

Possible value: None.

Example:

SP1659P# alarm

SP1659P(alarm)# events

SP1659P(alarm-events)# end

SP1659P#

4.2.2 exit

Syntax: exit

Description: Back to the previous mode.

When you enter this command, your current position would move back to the previous mode. If you use this command in the top mode, you are still in the position of the top mode.

Argument: None.

Possible value: None.

Example:

SP1659P# trunk

SP1659P(trunk)# exit

SP1659P#

66

Page 67
Image 67