3.4.4 Detailed Counter

Interval is used to set the update frequency. Default update time is 3 seconds.

Parameter description:

yTx Byte: Total transmitted bytes.

yRx Byte: Total received bytes.

yTx Packet: The counting number of the packet transmitted.

yRx Packet: The counting number of the packet received.

yTx Collision: Number of collisions transmitting frames experienced.

yRx Error Packet: Number of bad packets received.

3.4.4 Detailed Counter

The function of Detail Counter collects any information and provides the counting about the traffic of the port, no matter the packet is good or bad. As below, the window can show only one port counter information at the same time. To see another port’s counter, you have to pull down the list of Select, then you will see the figures displayed about the port you had chosen. Each data field has 12-digit long. If the counting is overflow, the counter will be reset and restart counting. The data is updated every time interval defined by the user. The valid range is 3 to 10 seconds. The Refresh Interval is used to set the update frequency. Default update time is 3 seconds.

20

Page 21
Image 21
MicroNet Technology SP1659P user manual Detailed Counter