MicroNet Technology SP1659P set timer, show config, Argument none Possible value none Example

Models: SP1659P

1 123
Download 123 pages 31.25 Kb
Page 87
Image 87
set timer

set timer

Syntax: set timer <range> <join> <leave> <leaveall>

Description: To set gvrp join time, leave time, and leaveall time for each port. Argument:

<range> : port range, syntax 1,5-7, available from 1 to 26

<join>: join timer, available from 20 to 100

<leave>: leave timer, available from 60 to 300

<leaveall>: leaveall timer, available from 1000 to 5000 Leave Time must equal double Join Time at least.

Possible value:

<range> : 1 to 26

<join>: 20 to 100

<leave>: 60 to 300

<leaveall>: 1000 to 5000

Example:

SP1659P(gvrp)# set timer 2-8 25 80 2000

show config

Syntax: show config

Description: To display the gvrp configuration.

Argument: none

Possible value: none

Example:

SP1659P(gvrp)# show config

 

 

 

 

 

 

 

 

 

 

GVRP state: Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port Join Time Leave Time LeaveAll Time

 

Applicant

Registrar Restricted

 

 

 

 

 

 

 

 

 

---- --------- ---------- ------------- --------------- --------- ----------

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

20

60

1000

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

 

2

25

80

2000

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

 

3

25

80

2000

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

 

4

25

80

2000

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

 

5

25

80

2000

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

 

6

25

80

2000

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

 

7

25

80

2000

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

 

8

25

80

2000

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

20

60

1000

 

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

 

24

20

60

1000

 

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

 

25

20

60

1000

 

Normal

Normal

Disable

 

 

 

 

 

 

 

 

 

26

20

60

1000

 

Normal

Normal

Disable

show counter

Syntax: show counter

Description: Usage: show counter <port>

Argument: <port>: port number

Possible value: <port>: available from 1 to 26

Example:

SP1659P(gvrp)# show counter 2

GVRP Counter port: 2

Counter Name

Received Transmitted

 

 

 

--------------------

-------- -----------

 

86

Page 87
Image 87
MicroNet Technology SP1659P user manual set timer, show config, Argument none Possible value none Example, show counter