<mode>: 0 or 1

Example:

SP1659P(802.1x)# set mode 2 1

SP1659P(802.1x)#

set port-control

Syntax: set port-control <port-range> <authorized>

Description: To set up 802.1X status of each port. Argument:

<port range> : syntax 1,5-7, available from 1 to 24

<authorized> : Set up the status of each port 0:ForceUnauthorized 1:ForceAuthorized

2:Auto

Possible value:

<port range> : 1 to 24

<authorized> : 0, 1 or 2

Example:

SP1659P(802.1x)# set port-control 2 2

set quiet-period

Syntax:

set quiet-period <port-range> <sec> Description:

A timer used by the Authenticator state machine to define periods of time during when it will not attempt to acquire a Supplicant.

Argument:

<port range> : syntax 1,5-7, available from 1 to 24

<sec> : timer , range 0-65535

Possible value:

<port range> : 1 to 24

<sec> : 0-65535, default is 60

Example:

SP1659P(802.1x)# set quiet-period 2 30

set reAuthEnabled

Syntax: set reAuthEnabled <port-range> <ebl>

Description: A constant that define whether regular reauthentication will take place on this port. Argument:

<port range> : syntax 1,5-7, available from 1 to 24 <ebl> :

0:OFF Disable reauthentication 1:ON Enable reauthentication

Possible value:

<port range> : 1 to 24

<ebl> : 0 or 1, default is 1

Example:

SP1659P(802.1x)# set reAuthEnabled 2 1

set reAuthMax

70