MicroNet Technology SP1659P set Syntax, Syntax show, Possible value # 1 to Example, Argument

Models: SP1659P

1 123
Download 123 pages 31.25 Kb
Page 78
Image 78

5 Authentication Failure

v

6User Login

7User Logout

8STP Topology Changed

9STP Disabled

10STP Enabled

11LACP Disabled

12LACP Enabled

13LACP Member Added

14LACP Port Failure

15GVRP Disabled

16GVRP Enabled

17Port-based Vlan Enabled

18Tag-based Vlan Enabled

19Module Inserted

20Module Removed

21Moudle Media Swapped

22PoE Failure

show

Syntax: show

Description: The Show for alarm here is used to display the configuration of Trap, SMS or E-mail.

Argument: None.

Possible value: None.

Example:

SP1659P(alarm)# show events

SP1659P(alarm)# show email

SP1659P(alarm)# show sms

<<sms>>

del

Syntax:

del phone-number <#> del server-user

Description: To delete sms phone number, sms server, user account and password.

Argument: <#>: mobile phone number, range: 1 to 6

Possible value: <#>: 1 to 6

Example:

SP1659P(alarm-sms)# del phone-number 3

SP1659P(alarm-sms)# del server-user

set

Syntax:

set server <ip>

set user <username>

set phone-number <#> <phone-number>

Description: The Set here is used for the configuration of SMS server, username, password and phone number.

Argument:

<ip>: SMS server ip

<username>: SMS server account and password

<#>: mobile phone number, range: 1 to 6

77

Page 78
Image 78
MicroNet Technology SP1659P user manual set Syntax, Syntax show, Argument None Possible value None Example