MicroNet Technology SP1659P user manual Alarm, Event, y reAuthPeriod1-65535 s, y max. Request1-10

Models: SP1659P

1 123
Download 123 pages 31.25 Kb
Page 51
Image 51
yreAuthPeriod(1-65535 s):

Choose whether regular authentication will take place in this port.

Default: ON

yreAuthPeriod(1-65535 s):

A non-zero number seconds between the periodic re-authentication of the supplicant.

Default: 3600

ymax. Request(1-10):

The maximum of number times that the authenticator will retransmit an EAP Request to the supplicant before it times out the authentication session. The valid range: 1 – 10.

Default: 2 times

ysuppTimeout(1-65535 s):

A timeout condition in the exchange between the authenticator and the supplicant. The valid range: 1 –65535.

Default: 30 seconds.

yserverTimeout(1-65535 s):

A timeout condition in the exchange between the authenticator and the authentication server. The valid range: 1 –65535.

Default: 30 seconds

3.15 Alarm

3.15.1Event

The Trap Events Configuration function is used to enable the switch to send out the trap information while pre-defined trap events occurred. The switch offers 24 different trap events to users for switch management. The trap information can be sent out in three ways, including email, mobile phone SMS (short message system) and trap. The message will be sent while users tick (;) the trap event individually on the web page shown as below.

50

Page 51
Image 51
MicroNet Technology SP1659P user manual Alarm, Event, y reAuthPeriod1-65535 s, y max. Request1-10, y suppTimeout1-65535 s