set suppTimeout

Example:

SP1659P(802.1x)# set state 192.168.1.115 1812 WinRadius

set suppTimeout

Syntax: set suppTimeout <port-range> <sec> Description:

A timer used by the Backend Authentication state machine in order to determine timeout conditions in the exchanges between the Authenticator and the Supplicant or Authentication Server. The initial value of this timer is either suppTimeout or serverTimeout, as determined by the operation of the Backend Authentication state machine.

Argument:

<port range> : syntax 1,5-7, available from 1 to 24

<sec> : timer , range 1-65535

Possible value:

<port range> : 1 to 24

<sec> : 1-65535, default is 30

Example:

SP1659P(802.1x)# set suppTimeout 2 30

set txPeriod

Syntax: set txPeriod <port-range> <sec>

Description: A timer used by the Authenticator PAE state machine to determine when an EAPOL PDU is to be transmitted

Argument:

<port range> : syntax 1,5-7, available from 1 to 24

<sec> : timer , range 1-65535

Possible value:

<port range> : 1 to 24

<sec> : 1-65535, default is 30

Example:

SP1659P(802.1x)# set txPeriod 2 30

show mode

Syntax: show mode

Description: To display the mode of each port.

Argument: None

Possible value: None

Example:

SP1659P(802.1x)# show mode

Port Mode

====== ============

1Disable

2Multi-host

3Disable

4Disable

5Disable

6Disable

:

:

:

show parameter