Example:

SP1659P(bandwidth)# set egress-rate 1-16 299

set ingress-rate

Syntax: set ingress-rate <range> <data_rate>

Description: To setup the Ingress-rate of the port.

Argument:

<range>:syntax 1,5-7, available from 1 to 26

<data_rate>: 66-1024000(Kb). #1-24: 66-102400(Kb, # 25-26: 66-1024000(Kb)

Possible value:

<range>: 1 to 26

<data_rate>: #1-24: 66-102400(Kb), # 25-26: 66-1024000(Kb)

Example:

SP1659P(bandwidth)# set ingress-rate 1-16 100

set storm-rate

Syntax: set storm-rate <range> <data_rate>

Description: To setup the storm-ate of the port.

Argument:

<range>:syntax: 1,3-5, available from 1 to 5

1: Disable

2: Broadcast Storm Control

3:Multicast Storm Control

4:Unknown Unicast Storm Control

5:Broadcast, Multicast, Unknown Unicast Storm Control

<data_rate>: 1-100. The value must be the integer. The value 100 disables broadcast storm control.

Possible value:

<range>: 1 to 5

<data_rate>: 1-100.

Example:

SP1659P(bandwidth)# set storm-rate 2 99

show

Syntax: show

Description: To display all current settings of the bandwidth.

Argument: None

Possible value: None

Example:

SP1659P(bandwidth)# show

Port Ingress Rate(Kb) Egress Rate(Kb)

====== ================== =================

1

102400

102400

 

 

 

 

 

 

 

2

102400

102400

 

 

 

 

 

3

102400

102400

 

 

 

 

 

4

102400

102400

 

 

 

 

 

5

102400

102400

 

 

 

 

 

6

102400

102400

 

 

 

 

 

7

102400

102400

 

 

 

 

 

8

102400

102400

 

 

 

 

 

9

102400

102400

 

 

 

 

10

102400

102400

 

 

 

 

11

102400

102400

 

 

 

 

12

102400

102400