Positioning with Digital Inputs

Configuration for Positioning

 

 

4.4Configuration for Positioning

If you install the MR-J3-D01 I/O expansion you can use point table positioning, which allows you to select positions from a list of up to 256 table entries with a combination of eight digital inputs. Table 4-3 shows how binary input signals are encoded to address the point table entries.

 

 

 

Digital Input Signals

 

 

 

Selected Point

DI7

DI6

DI5

DI4

DI3

DI2

DI1

DI0

Table Entry

0

0

0

0

0

0

0

1

1

 

 

 

 

 

 

 

 

 

0

0

0

0

0

0

1

0

2

 

 

 

 

 

 

 

 

 

0

0

0

0

0

0

1

1

3

 

 

 

 

 

 

 

 

 

0

0

0

0

0

1

0

0

4

 

 

 

 

 

 

 

 

 

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

·

 

 

 

 

 

 

 

 

 

1

1

1

1

1

1

1

0

254

 

 

 

 

 

 

 

 

 

1

1

1

1

1

1

1

1

255

 

 

 

 

 

 

 

 

 

Table 4-3:Selection of point table entries with digital input signals

In the factory default configuration the incremental system is activated, which means that the absolute position detection system is turned off (PA03 “absolute position detection system”).In this mode the current position is not stored when the power is turned off and you must thus perform a home position return every time the amplifier is powered on. The default configuration also uses absolute target positions (PA01 “positioning control mode”).

No.

Code

Function

 

Description

 

 

 

PA01 ￿

*STY

Positioning control

0: Absolute target position values

 

 

 

 

mode

1: Incremental target position values

 

 

 

 

 

 

 

 

PA03 ￿

*ABS

Absolute position

0: Incremental system (absolute detection off)

 

 

detection system

1: Absolute position detection system on

 

 

 

 

 

 

 

 

PA05 ￿

*FTY

Feed length multi-

 

Needed here to scale the home position value to the physical coor-

 

 

plication factor

 

dinate system when a home position offset (shift) has been set.

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Multiplication

Range of the target

 

 

 

 

 

value

factor STM

position values

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

999.999 .. +999.999

 

 

 

 

 

 

 

 

 

 

 

 

 

1

10

9999.99 .. +9999.99

 

 

 

 

 

 

 

 

 

 

 

 

 

2

100

99999.9 .. +99999.9

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1000

999999 .. +999999

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4-4:Parameter reference

￿To activate this parameter you must switch the amplifier power off and on again.

MR-J3-T