Functional Test of Digital Input Positioning

Positioning with Digital Inputs

 

 

4.5Functional Test of Digital Input Positioning

Normally you need a simple controller to set the digital inputs used to select the point table position entries, for example a PC, a mini PLC or an HMI control terminal. This chapter explains how you can perform a thorough check of the functionality of the positioning control functions without needing to perform the additional work of programming and installing a controller.

Fig. 4-19 shows a test installation without an external controller. Note that the FX Simulation Box used in this setup can set a maximum of 14 digital inputs.

Servo motor

1-phase

200–230V AC

Motor

Encoder cable

￿MR-J3USBCBL3M Cable length: 3m

￿MR-J2CMP2

￿MR-J2M-CNT1TBL-M Cable length: 0.5–1m

￿MR-TB50

Encoder

PC

FX Simulation Box

24V DC

24V DC power supply

 

 

 

 

 

 

Fig. 4-19:Test setup for simulating positioning with digital inputs

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

The test setup shown above does not use any safety features for the tests (EMG. OFF). You

 

 

 

 

 

 

 

 

 

 

should thus only use this setup in a controlled test environment where errors cannot cause

 

 

 

 

 

 

any danger for personnel or equipment!

4 - 28