Enter the Full Status Counter.

Valid values are between 1 and 255.

x- Enter Number, or P - Previous Menu

Selection : _

Enter the number between 1 and 255 that is going to be the number of polling cycles (minus one) before a full status is requested from the network.

13From the Trunk Configuration menu, enter option 10 Error Threshold and the Error Threshold menu is displayed.

Enter the Error Threshold.

Valid values are between 1 and 10. The Error

Threshold must be less than or equal to the

Monitored Event Counter.

x- Enter Number, or P - Previous Menu

Selection : _

Enter a number that is less than or equal to the Monitored Event Count.

14From the Trunk Configuration menu, enter option 11 Monitored Event Count and the Monitored Event Count menu is displayed.

Enter the Monitored Event Count.

Valid values are between 1 and 10. The Monitored

Event Count must be greater than or equal to the

Error Threshold.

x- Enter Number, or P - Previous Menu

Selection : _

Enter a number between 1 and 10 that is greater than or equal to the Error Threshold.

49