NAD S170iAV owner manual Troubleshooting, Condition, Possible Causes, Possible Solutionss

Models: S170iAV

1 164
Download 164 pages 34.89 Kb
Page 37
Image 37
TROUBLESHOOTING

 

 

 

 

TROUBLESHOOTING

CONDITION

 

POSSIBLE CAUSE(S)

 

POSSIBLE SOLUTIONS(S)

 

 

 

 

NO SOUND FROM ALL CHANNELS

AC power unplugged

• Check AC cable, connection, and outlet

 

• power not switched on

disengage Tape Monitor

 

• outlet is un-powered

 

 

 

• Tape Monitor is engaged

 

 

 

 

 

 

 

NO SOUND FROM SOME CHANNELS

Faulty/missing cables

Check cables

 

• <Speaker setup> channel(s) set to “No”

• check <Speaker setup> menu

 

power-amp or speaker-connections faulty

• check power amp, cabling, and speakers

 

 

 

NO SOUND FROM SURROUND CHANNELS

• No surround listening mode is engaged

• Select appropriate listening mode

 

surround-channels set to “No” on <Speaker

• correct <Speakers setup> or <Levels setup>

 

 

setup> menu

 

settings

 

surround-channels level set too low on <Levels

 

 

 

 

setup> menu

 

 

 

 

 

NO SOUND FROM SUBWOOFER

• Subwoofer is off, unpowered, or improperly

Power-up subwoofer, check sub’s AC outlet or

 

 

connected

 

check connections

 

• subwoofer set to “No” on <Speaker setup>

• correct <Speakers setup> or <Levels setup>

 

 

menu

 

settings

 

• sub level set too low on <Levels setup> menu

 

 

 

 

 

NO SOUND FROM CENTER CHANNEL

• Source is a 2/0 (etc.) Dolby Digital or DTS

• Play a known 5.1-channel recording or select

 

 

recording without center channel

 

Dolby Pro Logic or Mono mode

 

• center set to “No” on <Speaker setup> menu

• correct <Speakers setup> or <Levels setup>

 

• center level set too low on <Levels setup> menu

 

settings

 

 

 

 

NO DOLBY DIGITAL/DTS

• Source’s digital output is not connected to an

Check connections

 

 

S170i digital input

 

 

 

 

 

 

S170I DOES NOT RESPOND TO HTR 2 REMOTE

• Batteries are flat or incorrectly inserted

Check batteries

 

• IR transmitter window on remote, or IR receiver

• check IR windows and ensure clear line-of-sight

 

 

window on S170i is obstructed

 

from remote to S170i

 

• S170i front panel is in very bright sunlight or

reduce sunlight/room lighting

 

 

ambient light

 

 

 

 

 

 

S170I DOES NOT RESPOND TO FRONT-PANEL

Microprocessor error

Power-down the S170i via the front-panel Power

COMMANDS

 

 

 

key and unplug it from the AC outlet

 

 

 

• wait five minutes, re-connect and power up

 

 

 

 

 

SVENSKA PORTUGUÊS ITALIANO ESPAÑOL DEUTSCH FRANÇAIS ENGLISH

37

Page 37
Image 37