Page 18 NDA-30122 Revision 1
INSTALLATION & CONFIGURATION Attendant Console Statistics Operations Manual
Database Support Console Stats requires one database of its own in the APM. The Console Stats
database (statcfg) was loaded during software installation from the release media
and contains default field entries, most of which should not be changed without
first consulting an NEC representative. T he statcfg database structure and contents
are described in the table below:
The only field in this database whose entry should be changed is the Max Days to
Keep Records. This value reflects the number of days fo r which attendant data is
maintained in the database and can be any number of days, from 1 to 730. If you
need to change this value, use the Database Administration option on the APM
System Administration Menu. Refer to the APM Operations Manual for more
detailed instructions.
Proceed to the next page to initialize the Console Stats components...
Field Name
Master File Definition
(statcfg)
App. File
Definition
(Statcfg)
Master
Database
(statcfg)
Type Size Min.
Value Max.
Value Data Type Default Entry
Automated Reports Dir A 25 ASCII /oai/log/stats/arpts
Non-Automated Reports Dir A 25 ASCII /oai/log/stats/nar pts
Login Reports Dir A 25 ASCII /oai/log/stats/lr pts
Log Directory A 25 ASCII /oai/log/stats
Report Generator Process A 25 ASCII /oai/app/stats/bin/rptgen
Database Name A 9 ASCII statsdb
Max Days to Keep Records N 3 1 730 Short Integer 365
Max DB Records to Query N 2 1 50 Short Integer 50
Attendant Statistics A 1 ASCII Y
Call Queue Statistics A 1 ASCII Y