155

Receive Buffer Overflows

Total number of frames received on this port which caused a buffer overflow.

Transmit Buffer Overflows

Total number of frames which could not be transmitted from this port because of transmit buffer overflow.

Long Frames

Total number of frames received on this port which exceeded the maximum frame length.

Short Frames

Total number of frames received on this port which were less that 18 bytes.

Duplicate Ring Number

Indicates the number of times a frame which contains a duplicate ring number in the RIF field has been seen by the port.

Invalid RIF RC Field

Indicates the number of times a frame which contains an illegal Routing Control field has been seen by the port.

RIF Length Exceeded

Indicates the number of times a frame which contains a RIF field which is too long has been seen by the port.

Explorer Overflow

Indicates the number of times that an explorer frame has been dropped because of explorer rate throttling.

Ring Number Mismatch

Indicates the number of times that an incoming frame did not correctly include the port’s ring number.

Config Loss

Number of configuration loss events after the port has completed the join process and then lost communication.

Config Loss Reason

Latest Config Loss error code. Possible values are:

None

Wire Fault - Wire fault.

CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641

Monitoring the Network with the Console

Page 171
Image 171
Olicom 8600, 8605 Receive Buffer Overflows, Transmit Buffer Overflows, Long Frames, Short Frames, Duplicate Ring Number