Station-CPort Information Screen

The Station-CPort Information screen is shown below.

Station Requested Access Protocol

Protocol requested for station access. This field displays the value of the Access Protocol Request subvector X'0E' transmitted in the Registration Request MAC frame. Possible values are TXI and TKP.

Station Access Protocol Response

Response to protocol request. This field displays the value of the Access Protocol Response subvector X'0F' received from the Registration Response MAC frame. Possible values are Access Denied and FDX+Wire Fault.

Station Individual Address Count

This field displays the number of individual addresses supported by the MAC and used in the Individual Address Count subvector X'21'. This field will always display the value 1.

Station Phantom Drive Support

This field displays the MAC’s support of Phantom Drive and Wire Fault detection. It indicates the value of the SPV(PD) variable and the value of the Phantom subvector X'0C' used in the Registration Request MAC frame. This field will always display Ph Drv+Wire Fault for Phantom Drive and Wire Fault support.