211

Appendix B. Cable and Pin Information

This appendix provides information on cables that can be used with the CrossFire 8600 Token-Ring Switch and the CrossFire 8605 Token-Ring Fiber Switch. It also provides minimum pin-out information so that you can verify that the cables that you are using are correctly wired.

Connecting to the Out-of-Band Management Port

Table 24 lists the type of cables that are used when connecting to the OBM port (labelled MANAGEMENT) on the front panel of the switch.

Cable Function

Cable Type or Cable Solution

 

 

Connect a modem to the

Connect one end of a straight-through

MANAGEMENT port.

TIA/EIA-232 modem cable to the

 

MANAGEMENT port and the other end to

 

the modem.

 

 

Connect a PC or other DTE

Connect one end of a crossover TIA/EIA-

device to the

232 cable to the MANAGEMENT port and

MANAGEMENT port.

the other end to the PC or DTE device

 

or

 

attach a null-modem adapter to the

 

MANAGEMENT port. Then, attach a

 

straight-through modem cable to the null-

 

modem adapter.

 

 

 

 

Table 24. Connecting to the Management Port

CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641

Cable and Pin Information