Serial Link Download Screen

Serial Link download is for downloading via the Out-of-Band management port. The Serial Link Download screen is shown below.

Proceed as described below to update the switch software:

1.Use a terminal emulation program, which supports the X-modem protocol.

2.Insert the upgrade disk in your terminal emulator drive.

3.If you have not already done so, start a console session.

4.Select Download/Upload on the main menu.

5.Select Serial Link Download.

6.Select Main Image Download.

7.Confirm the download. The download takes approximately 12 minutes at 9600 baud. Note, there is no validation of the image, before the flash is updated.

8.Start the X-modem download on the terminal.

Note: Do not interrupt the download, or the image will be corrupted and needs to be reloaded. During the download, the DIAG LED on the switch will be blinking.

9.When the download is complete, you will be prompted to reset the switch. Press Y to confirm the reset. The procedure is now complete. If the download was interrupted or the image was invalid, the switch will discover this during startup, and a new serial download must be performed prior to normal operation.