CTRL-P

132

Creating a Console Session Using a Modem

Use the Serial Link Configuration menu to configure the switch in order to communicate with a console via a modem.

Set your modem according to the table below.

Setting

Value

 

 

Echo

Off

 

 

Result codes

Off

 

 

Wait for connection

45 seconds

 

 

Pause between calls

6 seconds

 

 

Drop DTR between calls

Yes

 

 

Send CR between calls

Yes

 

 

Auto baud detect

On

 

 

Send init if CD high

Yes

 

 

Maximum dial attempts

999

 

 

Table 21. Modem Settings

 

Caution: Some modems use slightly different names for the options. It is important that your modem be configured correctly. The settings shown in italics are particularly important. If your modem is not configured correctly, the connection may cause the switch to reset.

Start the console by pressing ENTER. If a Telnet session is active, press ENTER at the console to terminate the Telnet session and press ENTER again to start the console session.

Stopping the Console Session

Pressing returns the console session to the main menu, and pressing CTRL- B returns to the greeting menu.