Olicom 8605 Min Transmit Priority, Error High Threshold, Error Low Threshold, Cfg Loss Threshold

Models: 8605 8600

1 250
Download 250 pages 47.96 Kb
Page 124
Image 124

108

Min Transmit Priority

The minimum Token-Ring frame priority that will be used for transmits. Possible values are 06. The default value is 4.

Error High Threshold

This field is only valid when Forwarding Mode is set to auto, and is used to force a port to store & forward mode when the percentage of errors detected in the Sampling Interval is more than the error high threshold. Possible values are 0100 percent. The default value is 10 percent.

Error Low Threshold

This field is only valid when Forwarding Mode is set to auto, and is used to return a port to cut-throughmode when the percentage of errors detected in the Sampling Interval is less than the error low threshold. Possible values are 0100 percent. The default value is 1 percent.

Error Sampling Interval

This field is only valid when Forwarding Mode is set to auto, and specifies a sampling period in minutes. The sampling period is used when counting errors to determine a ports forwarding mode. Possible values are 160 minutes. The default value is 10.

Cfg Loss Threshold

Configuration loss occurs when a port completes a connection, allows data traffic to flow, and subsequently closes. This threshold is used to control the number of configuration losses that can occur within the Cfg Loss Sampling Interval. When the threshold is exceeded, the port is disabled and must be enabled via this screen or an SNMP manager. Possible values are 1100. The default value is 8.

Cfg Loss Sampling Interval

Specifies a sampling period in minutes. The number of configuration losses occurring within this interval is compare to the Cfg Loss Threshold to determine if a port should be disabled. Possible values are 160 minutes. The default value is 10.

Note: If you change any configuration parameters of a connected port, the port will close and reopen and you will lose all address information and statistics for that port.

CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641

Switch Configuration

Page 124
Image 124
Olicom 8605 Min Transmit Priority, Error High Threshold, Error Low Threshold, Error Sampling Interval, Cfg Loss Threshold