4 | Turning on the Power |
| |
|
|
4.1 Introduction to the Two Display Modes
The pump motor has two modes of operation defined by whether or not the motor is running. Refer to Table
| Table | |
|
|
|
Condition | Status During | Status During |
| Stopped Display Mode | Running Display Mode |
ON/OFF Switch | ON | ON |
|
|
|
Motor | STOPPED | RUNNING |
|
|
|
Pump | STOPPED | RUNNING |
|
|
|
Display | FLASHING | NOT FLASHING |
|
|
|
Green LEDs | NOT FLASHING | FLASHING |
|
|
|
Fluid | NOT FLOWING | FLOWING |
|
|
|
4.2 Using the ON/OFF Switch
When the ON/OFF switch is pushed upwards the unit’s power is on. When the switch is pushed downward, the unit’s power is off and the top of the switch labeled “0” is visible.
4.3 The STOPPED Display Mode
To enter the STOPPED Display Mode, do the following:
1.Plug in the pump motor to a convenient ac wall outlet. Use ac power within the range of 90 to 130 Vac (for 115 Vac units) or 190 to 260 Vac (for 220 Vac units).
NOTE
A line filter is already installed in the pump motor.
2.Attach the pump(s). Refer to Section 3.1.