Panasonic WJ-HD100 operating instructions Connections with PS Data Equipment

Models: WJ-HD100

1 60
Download 60 pages 45.63 Kb
Page 11
Image 11
■Connections with PS • Data Equipment

Connections with PS Data Equipment

Camera

Camera In

POWER

ON Manual background

OFFManual background

Camera Out Manual background

Video In

POWER

ON Manual background

OFFManual background

If the cable is locally procured, make sure it is data grade cable suitable for RS-485 communication. A 2- wire twisted pair shielded cable, BELDEN 9406 or equivalent should be used. Pin assignments and data flow are shown below.

 

No.

Name

Data Flow

No.

 

Controller

1

1

GND

 

1

 

 

 

end

 

2

RX(B)

WJ-HD100

WV-CU360

2

 

 

 

1

 

3

RX(A)

WJ-HD100

WV-CU360

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

TX(B)

WJ-HD100

WV-CU360

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

TX(A)

WJ-HD100

WV-CU360

5

 

 

 

 

 

 

 

6

6

 

6

GND

 

6

 

 

 

 

 

 

 

Data Multiplex Unit

Video Monitor

ALARM

ALARM SUSPEND

Data Multiplex Unit WJ-MP204

DATA Port

Video Multiplexer

POWER

ON

OFF

Note:

Set the field rate to

7.5fps or slower when connecting the Camera SW Out signal with the video multiplexer.

CAM SW

 

Rec

 

In

 

Out

 

 

 

Play

 

 

In

 

IN

 

IN

 

OUT

 

OUT

 

 

 

 

AUDIO

CAMERA

VIDEO MONITOR OUT

RS-232CDATA

SW OUT

 

(PLAY)

 

 

 

 

DATA Port

 

Multi Screen

Video In

 

Out

 

 

 

 

 

 

 

DATA Port

Digital Disk Recorder WJ-HD100

 

 

 

(EXT REC) JOG-CLICK JOG-LEFT JOG-RIGHT

G ALARM SEARCH STEP

REW/FF STOP/SETUP PLAY REC G OUT IN PLAY OUT

REC OUT AUTO OFF OUT DISK END OUT OUT IN

G RECALL OUT RECOVER OUT RESET IN

POWER

ON

SIGNAL GND

IN

 

 

 

 

 

OFF

MODE

REMOTE

TIME

SERIES

ALARM

 

 

 

ADJUST

RECORD

 

 

Camera SW

Video In Monitor Out

Out

 

 

DATA Port

 

System Controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set the termination to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

ON for the units at both

 

 

 

 

 

 

 

 

 

 

 

 

 

ends of the chain, and to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF for units in the

 

 

 

MODE

 

 

 

 

middle.

System Controller with PS•Data

Capability

PSData equipment must be set up for communication as follows:

Protocol selection: PS DATA

Unit Address: Set an address unique in the chain.

Baud rate, data bit length, parity check, stop bit: Choose the same settings as used for the other equipment in the chain.

Recommended video multiplexers are Panasonic’s WJ-FS series or similar models having specifications as follows.

Switching recognition signal is located within 8H prior to the end of vertical blanking.