Panasonic WJ-HD100 Alarm Setup, Alarm Recording Mode 301 REC MODE, Alarm Buzzer 305 ALARM BUZZER

Models: WJ-HD100

1 60
Download 60 pages 45.63 Kb
Page 27
Image 27
■ALARM SETUP

ALARM SETUP

The digital disk recorder accepts an alarm signal supplied from connected device such as a camera or camera site equipment. The recorder also generates an alarm signal itself when the preset motion detection activates.

Any alarm signal starts alarm recording with the preset recording mode, field rate and picture quality. Alarm recording stops when the preset time has elapsed, the [STOP] [SETUP/ESC] button on the front panel is pressed, or the alarm RESET IN is supplied from the connected device. The recorder outputs an alarm recovery signal from the rear panel.

Alarm Recording Mode 301 REC MODE

 

ALARM SETUP

REC MODE

 

 

SF- 12H

REC

RATE

15FPS

 

REC

QUALITY

10(1-10)

DURATION

10S

ALARM

BUZZER

ON

VMD SETUP

OFF

This item specifies the recording mode to be applied exclu- sively to the sequence after an alarm input. The setting procedure and parameters are the same as for REC SETUP described earlier.

 

 

 

 

REC MODE

SF- 12H

 

REC

RATE

15FPS

 

REC

QUALITY

10(1-10)

DISPLAY SELECT

LCD CONTRAST

Alarm Recording Duration 304 DURATION

This setting specifies the duration of alarm recording and related functions after an alarm input. Functions active dur- ing alarm recording are buzzer beeping, ALARM LED indi- cation, "ALARM" status display, and the ALARM OUT sig- nal.

 

 

 

DURATION

10S

 

ALARM BUZZER

ON

 

VMD SETUP

OFF

 

DISPLAY SELECT

LCD CONTRAST

1.Move the cursor to DURATION with the [] or [] but- ton.

2.Select the desired duration with the JogDial. The default value is 10 seconds.

The unit will revert to the previous status when the time has elapsed.

10S: 10 seconds

20S: 20 seconds

30S: 30 seconds

1M: 1 minute

2M: 2 minutes

3M: 3 minutes

6M: 6 minutes

MANUAL: Recording continues for as long as there is alarm input or for at least 10 seconds, even if the alarm input turns off earlier.

CONTINUE: Recording continues until the stop button on the front panel is pressed, or the RESET IN sig- nal is supplied.

OFF: Neither recording nor alarm logging is implement- ed.

Alarm Buzzer

305 ALARM BUZZER

 

ALARM SETUP

REC MODE

SF- 12H

REC

RATE

15FPS

REC

QUALITY

10(1-10)

DURATION

10S

ALARM

BUZZER

ON

 

VMD SETUP

OFF

DISPLAY SELECT

LCD CONTRAST

1.Move the cursor to ALARM BUZZER with the up [] or down [] button.

27

Page 27
Image 27
Panasonic WJ-HD100 Alarm Setup, Alarm Recording Mode 301 REC MODE, Alarm Recording Duration 304 DURATION, SF- 12H