■COMMUNICATION SETUP

COMMUNICATION SETUP

Communication parameters are set to match those of the connected devices and the system configuration.

COMMUNICATION SETUP

PROTOCOL

PS•DATA

UNIT ADDRESS

1

BAUD RATE

9600

DATA BIT

8

PARITY CHECK

NONE

STOP BIT

1

WAIT TIME

OFF

PROTOCOL

PS•DATA

UNIT ADDRESS

1

BAUD RATE

9600

DATA BIT

8

 

DISPLAY SELECT

 

LCD CONTRAST

1.Move the cursor to UNIT ADDRESS with the [] or [] button.

2.Select the address with the JogDial. The default value is 1.

From 1 to 96: Set an address unique in the chain.

Protocol

501 PROTOCOL

PROTOCOL

PS.DATA

UNIT ADDRESS

1

BAUD RATE

9600

DATA BIT

8

PARITY CHECK

NONE

 

DISPLAY SELECT

 

LCD CONTRAST

1.Move the cursor to PROTOCOL with the [] or [] but- ton.

2.Select a suitable protocol with the JogDial. The default is PS DATA.

PS DATA: Select when the communication chain uses the PS DATA protocol. This selection enables the DATA terminal on the rear panel for communication.

VCR: Select when other than PS DATA is used.

This selection enables the RS-232C terminal on the rear panel for communication.

Note: Parallel use of the DATA and RS-232C terminals is not possible.

Unit Address

502 UNIT ADDRESS

The unit address can be set either from the setup menu on the monitor or using the DIP switch on the rear panel. The address setup with the DIP switch has priority over the setup on the monitor menu. Make certain to set DIP switch- es #1 through #4 to OFF before setting the unit address on the monitor.

Baud Rate

503 BAUD RATE

UNIT ADDRESS

1

BAUD RATE

9600

DATA BIT

8

PARITY CHECK

NONE

 

DISPLAY SELECT

 

LCD CONTRAST

1.Move the cursor to BAUD RATE with the [] or [] but- ton.

2.Select the rate with the JogDial.

The default value is 9 600 bits per second.

4800: 4 800 bps

9600: 9 600 bps

19200: 19 200 bps

Data Bit

504 DATA BIT

BAUD RATE

9600

DATA BIT

8

PARITY CHECK

NONE

STOP BIT

1

 

DISPLAY SELECT

 

LCD CONTRAST

1. Move the cursor to DATA BIT with the [] or [] button.

30

Page 30
Image 30
Panasonic WJ-HD100 Communication Setup, Protocol 501 PROTOCOL, Unit Address 502 UNIT ADDRESS, Baud Rate 503 BAUD RATE