Miscellaneous Control

Miscellaneous Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Playback Speed

LTM:n

LTM

n=0-F

 

 

 

 

n=0

11 ............. Fastest

 

 

 

n=1

10

 

 

 

n=2

9

 

 

 

n=3

8

 

 

 

n=4

7

 

 

 

n=5

6

 

 

 

n=6

5

 

 

 

n=7

4

 

 

 

n=8

3

 

 

 

n=9

2

 

 

 

n=A

1

 

 

 

n=B

1/2

 

 

 

n=C

1/4

 

 

 

n=D

1/8

 

 

 

n=E

1/16

 

 

 

n=F

1/32 ...........Slowest

 

 

 

 

 

Data Copy Cancel

ZDC

ZDC

 

 

Data Copy

ZDP:nn

ZDP

nn=00 Copy until the card is full

 

 

 

nn=01 Copy 1 field

 

 

 

nn=08 Copy 8 fields

 

 

 

nn=16 Copy 16 fields

 

 

 

nn=32 Copy 32 fields

 

 

 

nn=48 Copy 48 fields

Time&Date Search

ZTS:yyyymmddhhnnss

ZTS

yyyy=Year

 

 

 

mm=Month

 

 

 

dd=Day

 

 

 

hh=Hour (24-hour system)

 

 

 

nn=Minute

 

 

 

ss=Second

 

 

 

 

 

Communication Check

RCK

RCK

 

 

Data Log Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Log Total Size Inquiry

ILB:k

ILB:k:bbb

k=0

Alarm log

 

 

 

bbb=001 to 099 (in decimal)

Log Erase

ILC:k

ILC:k

k=0

Alarm log

Log Recorded

ILQ:k

ILQ:k:bbb:(:E)

k=0

Alarm log

Size Inquiry

 

 

bbb=001 to 099 (in decimal)

 

 

 

E=Overwrite

Log Readout

ILR:k:sss:mmm

ILR:k:<log data s1>s1

 

 

<log data s2>s2

 

 

<log data sn>F

k=0 Alarm log sss=001-099 Start Address mmm=001-099 Decimal # of log <log data sn>=yymmddhhnnss sn=0-9 and F Cyclic number (F is put at data end)

Media Control

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Disk End Notice Setup

MDE:n

MDE

n=0

End is not notified

 

 

 

n=1

End is notified

Disk End Notice

 

HDE

 

 

49

Page 48
Image 48