microprocessor control 6

microprocessor controlled muting

The Crest X-Series of Consoles* is equipped with a micro-con- trolled Mute Controller which permits the user to set-up a series of Mute Scenes, each controlling any combination of channels and outputs.These Scenes can then be recalled, either singly or in combination, to allow the operator to easily control the mutes during a performance.

The Mute Controller features 128 Sequenced Scenes (Patches) along with 8 Manual Mute Scenes.The 128 Patches can be stepped through using a single button, or remotely activated by the use of MIDI patch-change commands.The Patches can be combined with the Manual Scenes to allow different combinations of Channel mutes.

The following is a overview of the controls and indicators of the Mute Controller and the Channels (see diagrams on previous page).The following information pertains to X-Eight consoles with Rev 1.12 firmware, and X-Monitor consoles with Rev 1.00 firmware.

12-12-01 Supplementary information....

1)To perform “FULL FACTORY RESET” of Micro Mute and VCA settings hold up/down buttons upon power-up. This will clear all memory and restore Micro Controller to factory presets.

2)Do not use the "uP" parameter with the setting "OFF" in the utility menu until a newer EPROM version is released. Please submit your console serial # and shipping address to Roffi@CrestAudio.com if you wish to be on an EPROM distribution list for this event.

3)EOF stands for Edit On the Fly. A new parameter offered in the utility menu. When selected it allows for spontaneous removal of a mute you have programmed in as part of a current scene.