Pelco C1977M-D manual Configuration Default Settings Description

Models: C1977M-D

1 92
Download 92 pages 48.81 Kb
Page 34
Image 34

The following table gives detailed information about the items on the General Settings Configuration Page, together with the default factory settings:

 

Table B. General Settings

 

 

 

Configuration

Default

 

Item

Settings

Description

 

 

 

Name

none

The unit name helps the user identify a particular

 

 

unit, especially if many PelcoNet Transmission Sys-

 

 

tems are on the network.

 

 

 

ID

none

The ID serves as a machine-readable name. The ID

 

 

can be read at any time. Reading is facilitated re-

 

 

motely via UDP/IP, letting a management system

 

 

monitor the unit.

 

 

 

Password level

none

This field lets you set the password at either the

 

 

user or service level.

 

 

 

Password

none

The unit can be password-protected to prevent unau-

 

 

thorized tampering with the configuration. The pass-

 

 

word needs to be repeated correctly in the confirm box

 

 

before password protection is activated. Once pass-

 

 

word protection is enabled, you need to log in before

 

 

the configuration pages can be accessed (Figure 27).

 

 

 

IP address

192.168.0.1

Enter a unique IP address that is valid for your network.

 

(192.168.0.2 for

The pre-configured default IP address allows for easy

 

receiver)

configuration in closed environments. You can use a

 

 

crossed cable to directly connect to a PC. Also, the

 

 

PC’s IP address and subnet mask must match the

 

 

default IP address.

 

 

NOTE: Changing the IP address also affects the

 

 

current browser connection. You will have to enter

 

 

the new URL to regain connectivity to the unit.

 

 

 

Subnet mask

255.255.255.0

Exchange with a valid subnet mask for your network,

 

 

if subnets are in use.

 

 

 

Gateway IP

none

The IP address of the router. Typically used in a

 

 

WAN environment.

 

 

 

Base Port

25000

This setting lets the user designate which TCP/IP

 

 

ports PelcoNet uses for transmission, video, audio,

 

 

and control. For example, the default setting of

 

 

25000 means PelcoNet will use TCP ports 25000-

 

 

25001 and UDP ports 25002-25011 (12 ports total)

 

 

for all video and control data.

 

 

 

Mail server

none

Only required if the mail-sending feature is to be

IP address

 

used. Outgoing e-mail is sent to the mail server

 

 

(SMTP server) at the given IP address.

 

 

 

 

 

(Continued on next page)

[ 34 ] Pelco Manual C1977M-D (6/02)