Connecting a Pelconet Transmitter To The CM6800 ASCII Port

Refer to Figure 51. This configuration lets an operator view and control cameras with a PC using a web browser. (The operator’s PC is not shown on the diagram.) All settings are done in the CM6800 manager program or through a CM6800 menu. Note the following:

Port 2 defaults to ASCII and RS-232.

Ports 7 and 8 can be set to ASCII and RS-232 by using the CM6800 manager program (refer to Figure 51) or by using a CM6800 menu (refer to Figure 52).

Pelco recommends using Port 2.

CM6800-48X8

PORTSETUP

PROTOCOL

CM6800ASCII

®

COAXITRON

PELCONET

SPECTRA

00669

6800MATRIXCOM2 PORTSETTINGS:

BAUDRATE 9600 DATABITS 8 PARITY ODD STOPBIT 1

 

 

PELCONETCM6800-48X8

TRANSPARENTDATAPORT COM2 2RXD...................................................8TXD 3TXD...................................................1RXD 5GND..................................................5GND

CONNECTPELCONETTO6800VIARS-232PORT

 

PelcoNet with CM6800 to Provide Remote Control

VIDEOIN

PELCONET TRANSMITTER

CONTROL TERMINAL

3-TX I/OALARM

TRANSPARENTDATAPORT

INTERNETUSINGEXPLORER, TRANSPARENTSET DATA SETTINGS:PORT RATEBAUD9600 BITSDATA8 RITYPAODD BITSTOP1

 

 

RX2-

GND5-

 

 

TONETWORK(LAN/WAN)

 

 

 

 

 

Figure 51. Using

Pelco Manual C1977M-D (6/02)

[ 85 ]