1.Connect a PV130 Converter to the RS-232 port on the front of the PelcoNet Transmission System receiver. The data format should be 9600 baud, 8 data bits, odd parity, and 1 stop bit.

2.Connect the black and white striped wire from the power supply that came with the converter to the converter’s +12 VDC terminal and the solid black wire to the GND terminal.

3.Connect TD(A) on the converter to terminal 7 on the wall block. Connect TD(B) on the converter to terminal 8 on the wall block. Connect RD(A) on the converter to terminal 2 on the wall block. Connect RD(B) on the converter to terminal 1 on the wall block.

4.Connect the 12 VAC power supply to terminals 3 and 4 on the wall block.

5.Connect the wall block to the KBD4000 with an RJ-45 straight cable.

6.Connect the monitor.

7.Repeat steps 1 and 2 for the transmitter.

8.Connect TD(A) on the converter to terminal 2 on the wall block. Connect TD(B) on the converter to terminal 1 on the wall block. Connect RD(A) on the converter to terminal 7 on the wall block. Connect RD(B) on the converter to terminal 8 on the wall block.

9.Connect the wall block to COM IN on the multiplexer with an RJ-45 straight cable.

10.Connect MAIN video output from the multiplexer to the transmitter.

Pelco Manual C1977M-D (6/02)

[ 73 ]

Page 73
Image 73
Pelco manual Pelco Manual C1977M-D 6/02