Connecting PelcoNet To a CM6800 and KBD200 For Remote ASCII Control

Refer to Figure 54. This configuration lets an operator view and control cameras with a remote KBD200 keyboard. All settings are done in the CM6800 manager program or through a CM6800 menu. Note the following:

Port 2 defaults to ASCII and RS-232.

Ports 7 and 8 can be set to ASCII and RS-232 by using the CM6800 manager program (refer to Figure 52) or by using a CM6800 menu (refer to Figure 53).

Pelco recommends using Port 2.

PELCONET REMOTE KBD200 ASCII MODE SETUP

STRAIGHT CABLE SUPPLIED

RJ-45 WALL BLOCK AND

TD(B)

TD(A)

8

RD(A)

RD(B)

ORDEREDPV130SEPARATELY

 

 

1

 

 

 

 

7

2

 

 

 

 

6

3

 

 

 

 

5

4

 

 

 

 

 

TD(A)

 

 

 

 

 

TD(B)

 

 

 

 

 

GND

 

 

 

 

 

+12 VDC

 

 

 

GND

12V

PV130

 

 

VIDEOOUT

 

2-RX

3-TX

5-GND

TRANSPARENTDATAPORT

PELCONET RECEIVER

CONTROL TERMINAL

ALARMI/O

TO NETWORK (LAN / WAN)

KBD200

FIRMWAREVER.4.0ORLATERREQUIRED.

SETKEYBOARDDIPSWITCHES-SWITCH 6ON,SWITCHES5AND8OFF,SWITCHES

1-4FORADDRESSACCORDINGTOTHE

TABLEINTHEKBD200MANUAL.

 

NOTE:

 

 

 

 

PROTOCOL

 

12VAC

 

®

 

 

 

 

SPECTRACOAXITRON

 

 

USINGINTERNETEXPLORER,

SETTRANSPARENTDATASETTINGS

ONBOTHPELCONETRECEIVERAND TRANSMITTER:

BAUDRATE 9600

DATABITS 8 PARITY ODD STOPBIT 1

CM6800-48X8

VIDEOIN

PELCONET TRANSMITTER

2-RX

3-TX

5-GND

CONTROL TERMINAL

ALARMI/O

TONETWORK(LAN/WAN)

 

 

 

 

00668

6800MATRIXCOM2 PORTSETTINGS:

BAUDRATE 9600

DATABITS 8

PARITY ODD

STOPBIT 1

 

 

CM6800-48X8

COM2 8TXD

1RXD

5GND

 

 

PELCONET

TRANSPARENTDATAPORT

2RXD

3TXD

5GND

 

 

TRANSPARENT DATA PORT

CONNECT PELCONET TO 6800 VIA RS-232 PORT

Figure 54. Using PelcoNet with CM6800 and KBD200 to Provide Remote Control

Pelco Manual C1977M-D (6/02)

[ 87 ]

Page 87
Image 87
Pelco C1977M-D manual Pelconet Remote KBD200 Ascii Mode Setup