1.Connect a PV130 Converter to the RS-232 port on the front of the PelcoNet Transmission System receiver. The data format should be 4800 baud, 8 data bits, even parity, and 1 stop bit.

2.Connect the black and white striped wire from the power supply that came with the converter to the converter’s +12 VDC terminal and the solid black wire to the GND terminal.

3.Connect TD(A) on the converter to terminal 7 on the wall block. Connect TD(B) on the converter to terminal 8 on the wall block. Connect RD(A) on the converter to terminal 2 on the wall block. Connect RD(B) on the converter to terminal 1 on the wall block.

4.Connect a straight RJ-45 cable from the wall block to the supplied Pelco power pack.

5.Connect a straight RJ-45 cable from the keyboard input connector on the power pack to COM 1 on the keyboard.

6.Connect the monitor.

7.Repeat steps 1 and 2 for transmitter.

8.Connect TD(A) on the converter to terminal 2 on the wall block. Connect TD(B) on the converter to terminal 1 on the wall block. Connect RD(A) on the converter to terminal 7 on the wall block. Connect RD(B) on the converter to terminal 8 on the wall block.

9.Connect a flipped RJ-45 cable from the wall block to Sercom port 5 on the CC1’s rear panel.

10.Connect one of the three monitor outputs on the rear of the controller to the transmitter.

Pelco Manual C1977M-D (6/02)

[ 75 ]

Page 75
Image 75
Pelco manual Pelco Manual C1977M-D 6/02