SERVICE CABLE

SERVICE CABLE

The camera includes a service port that outputs camera video. Use it at the installation site to set up the field of view and to focus the camera.

Pelco offers an optional service cable (IX-SC) that plugs directly into the service port. To access the service port, you must slide down the front cover front cover down (refer to Figure 1 on page 8). The service cable has a male BNC output for most standard viewers.

NOTE: The ICS-SC and CST150 are not compatible with this camera. If you have any questions about service cable compatibility, contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international).

To assemble a service cable for the camera, purchase the following items from a local electronics supply store:

Qty Description

1 2.5 mm stereo plug (male)

1CPM 88 miniature coaxial connector

1RG174/U coaxial cable

11/8-inch shrink fit tubing, 1/2-inch long

To assemble the cable:

1.Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directions supplied with the miniature coaxial connector.

2.Attach the 2.5 mm stereo plug to the other end of the coaxial cable (refer to Figure 6):

a.Remove the support sleeve from the plug.

b.Slip the shrink fit tubing and support sleeve over the end of the cable.

c.Prepare the cable:

(1)Strip back the outer jacket 0.318 inch (8.06 mm) inch from the end of the cable.

(2)Pull back the coaxial braid shield.

(3)Strip back the insulating material 0.125 inch (3.18 mm) inch to expose the center conductor.

d.Solder the center connector of the cable to the center pin of the plug.

e.Pull the coaxial braid shield back through the crimp pin and solder it to the top of the crimp pin arm.

f.Crimp the end of the crimp pin around the cable.

g.Heat the shrink fit tubing around the center conductor and shoulder pin.

h.Reassemble the support sleeve and the plug.

Figure 6. Attaching the 2.5 mm Monaural Headphone Plug

ì 2.5 mm Stereo Plug

ó

î Plug Shoulder Pin

r

ï Center Conductor

s

ñ Support Sleeve

t

Shrink Fit Tubing

Coaxial Cable

Coaxial Braid Shield

Crimp Pin Arm

12

C2953M-B (10/09)

Page 12
Image 12
Pelco C2953M-B manual Service Cable, Qty Description