Unsupervised Alarms
When an alarm is configured as an unsupervised alarm, the camera only activates an alarm when the normal alarm state (open or closed) changes.
Figure 12 illustrates the alarm and no alarm conditions of an unsupervised alarm input.
| NORMALLY CLOSED |
|
| NORMALLY OPEN |
NO ALARM |
|
| NO ALARM |
|
GND |
| +V | GND | +V |
ALARM |
|
| ALARM |
|
GND |
| +V | GND | +V |
ALARM |
|
| NO ALARM |
|
GND |
| +V | GND | +V |
NO ALARM | CUT |
| ALARM | CUT |
|
|
| ||
GND |
| +V | GND | +V |
| BYPASS |
|
| BYPASS |
Figure 12. Unsupervised Alarm Conditions
Figure 13 illustrates the wiring configuration for unsupervised alarm inputs.
NORMALLY CLOSED | NORMALLY OPEN |
A1
A1
Figure 13. Normally Closed and Normally Open Unsupervised Alarm Input Wiring
NOTE: A normally closed alarm input can be defeated with a bypass; a normally open input can be defeated with a cut.
Alarm Connections
Figure 14 shows how to wire the camera to an alarm.
ALARM A1
ALARM
Figure 14. Alarm Connections
16 |