Troubleshooting IBM- PC DOS / WINDOWS Installation Appendix A

SCSI interface card can’t communicate with drive

This means the device driver was not able to locate the proper SCSI

interface card in the PC.

1. Verify that the Pioneer CD-ROM Changer has been turned ON.

2.Make sure you are using the SCSI Cable that goes with your interface card. Not all DB 25 Centronics 50 pin cables are the same. Older Future Domain cards (TMC-845) use an HCA-108 Future Domain cable. Most current Future Domain SCSI interface cards require an Apple Signal SCSI cable; there will be an Apple sticker on the interface card. Use either a generic Apple Signal SCSI cable, or use a Future Domain cable # HCA-110.

For information about the correct cable to use with other SCSI cards, contact the SCSI interface card manufacturer or dealer.

3. Power down the computer and the Pioneer Changer and check to make sure the SCSI cables are securely attached to the computer and to the changer.

4. When Installing the Drivers, make sure you indicate the correct interface card you are using, so the correct driver is installed. Check the DEVICE driver line in the CONFIG.SYS to verify that the correct device driver has been installed:

DRD600.SYS must be used with a Future Domain or DD-C5002

DRD60ASP.SYS must be used with an ASPI compatible interface card

DRD60PS.SYS must be used with an IBM SCSI interface card.

“SCSI interface card can’t communicate with drive”

Continued on next page

A-2

Software Driver Installation Guide / Owner’s Manual