Appendix A Troubleshooting IBM- PC DOS / WINDOWS Installation
Time out waiting for initial bus free phase, status phase or data phase
This means you have some kind of problem with the SCSI cable or a problem with termination.
1. Power down the computer and the Pioneer Changer and
the cable. Make sure it is securely attached. If the problem persists, replace the cable.
2. Check termination. If the Pioneer Changer is the only device or the last device on the SCSI chain, termination should be ON. If it is in the middle of a SCSI chain, termination should be OFF.
The
Characters on the |
|
|
|
|
Inquiry ID=0 |
|
|
| This means there is a problem on the |
line are jumbled |
|
|
| SCSI chain. |
|
|
|
|
|
|
|
|
|
|
1. Check termination. If the Pioneer Changer is the only device or the last device on the SCSI Chain, termination should be ON. If it is in the middle of a SCSI Chain, termination should be OFF. The
2. Power down the computer and the changer, disconnect the cable
from the back of the computer and restart . If you get an error message that reads “Time Out During Selection Phase”, you may have a bad cable or a poor connection. Reseat the cable or change it and try again.
3. If the problem persists, it may be a interface card conflict, a bad
extension slot, or a problem with the interface card. Try changing the address of the interface card. Refer to interface card documentation. Try placing the interface card in another slot. Try replacing the interface card.
Owner’s Manual / Software Driver Installation Guide |