4.6.2 SNMP Target

This option allows you to configure the SNMP target to control where the SNMP traps (notifications) are sent. Traps are used to report an alarm or other asynchronous event about a managed IDL-2402 system. From the SNMP menu, click on SNMP Target. The following page is displayed.

 

SNMP Community Setup

Label

Description

 

 

 

Click on this button to create a new SNMP target. After you click on New, the following page is

 

displayed. Type in the IP Address, Name and Tag of the SNMP target, Address Port (Usually

 

SNMP uses UDP port 161 for general SNMP messages and UDP port 162 for SNMP trap

 

messages), and select Trap Version (V1 or V2c). Then click on Apply button. The Target Tag can

 

be the same with a Notify Tag; you can select the Notify Tag in the Use Notify Tag field. The

 

Notify Tag is created in the SNMP Notify table (see next section). When the Target Tag is the

 

same with a Notify Tag, the SNMP notification with that Notify Tag is sent to the Target with the

 

same tag.