5.18.4mode

Description Set downstream/upstream rate adaptive mode to init (rate automatically selected at start up only and does not change after that), dynamic (rate automatically selected at initialization and is continuously adapted during show time), or manual (rate changed manually)

Syntax mode {ds us} {init dynamic manual}

Parameter None

5.18.5noise

Description Set downstream/upstream minimum impulse noise protection. Syntax noise {ds us} <number>

Parameter

Name

Description

 

 

number

Noise (tenth symbols).

 

Valid values: 0~8 step 0.1

 

Default value: -

 

Type: Mandatory

 

 

5.18.6noisemargin

Description Set Downshift/Upshift Noise Margin in downstream/upstream direction

Syntax noisemargin {ds us} {downshift upshift} <number>

Parameter

Name

Description

 

 

number

Downshift/Upshift Noise Margin (tenth

 

symbols).

 

Valid values: 0~31 step 0.1

 

Default value: -

 

Type: Mandatory

 

 

- 353 -