SpectraLink 8020/8030 Wireless Telephone: Administration Guide for SIP

Message

Description

Action

Service Rej.

The SpectraLink 8000 SVP Server has

The handset will restart and attempt to

 

rejected a request from the handset.

re-register with the SpectraLink 8000

 

 

SVP Server, which should fix the

 

 

problem. Report to your administrator if

 

 

it keeps happening.

Storing Config

Handset is storing changes to handset

None. Informational only. The handset

 

configuration.

may display this briefly following a

 

 

configuration change or software

 

 

download.

SVP Service Rej.

The SpectraLink 8000 SVP Server has

The handset will restart and attempt to

 

rejected a request from the handset.

re-register with the SVP Server, which

 

 

should fix the problem. Report to your

 

 

administrator if it keeps happening.

System Busy

y…y = SVP Server IP Address.

All call paths are in use, try the call

yyy.yyy.yyy.yyy

SVP Server has reached call capacity.

again in a few minutes.

System Locked

SpectraLink 8000 SVP Server is

Try call again later, system has been

(with Busy Tone)

locked.

locked for maintenance.

TFTP

A failure has occurred during a TFTP

Error code 01, 02, 07, or 16 - check the

ERROR(x):yy

software download. (x) = The file

TFTP server configuration.

 

number which was being downloaded;

Error code 81, the handset will attempt

 

yy is an error code describing the

 

to download the file again.

 

particular failure. Possible error codes

 

For other messages, power off the

 

are:

 

handset, then turn it on again to retry

 

01 = TFTP server did not find the

 

the download. If the error repeats, note

 

requested file.

 

it and contact Polycom Customer

 

02 = Access violation (reported from

 

Support.

 

TFTP server).

 

 

07 = TFTP server reported "No such

 

 

user" error.

 

 

16 = No TFTP server address.

 

 

81 = File put into memory did not CRC.

 

 

FF = Timeout error. TFTP server did

 

 

not respond within a specified period of

 

 

time.

 

Too Many Errors

The handset continues to reset and

Fatal error. Return handset to Polycom.

 

cannot be recovered.

 

Unknown

A phrase is missing from the phintl file.

Download new software from the

xx:yy:zz

 

Polycom website per Software

 

 

Maintenance.

Unsupported

The proxy server has requested using

Check proxy server configuration for

Codec

a codec not supported by the handset.

supported codecs and reconfigure if

 

 

necessary.

Updating …

The handset is internally updating its

None. The handset may do this briefly

 

software images.

after a download. This is informational

 

 

only.

96

PN: 1725-36038-001_B.doc

Page 96
Image 96
Polycom 8020, 8030, 1725-36038-001 manual Maintenance