Q-Logic B - Command Line Interface, Test Command, test x external, show port, 59021-05 A, B-67

Models: 59021-05

1 180
Download 180 pages 45.41 Kb
Page 155
Image 155
test x external

￿

B – Command Line Interface

Test Command

 

 

 

 

To run an external loopback test, enter the following command. A loopback plug must be installed for this test to pass.

test x external

5.A series of test parameters are displayed on the screen. Press the Enter key to accept each default parameter value, or type a new value for each parameter and press the Enter key. The TestLength parameter is the number of frames sent, the FrameSize (256 byte maximum in some cases) parameter is the number of bytes in each frame, and the DataPattern parameter is the pattern in the payload.

6.After the test type has been chosen and the command executed, a message on the screen will appear detailing the test results.

7.After the test is run, put the port back into online state by entering the following command (x = port number) and pressing the Enter key.

set port x state online

8.To verify port is back online, enter the following command and press the Enter key. The contents of the AdminState field should display be “Online”.

show port x

The online loopback (node-to-node) test can test only one port at a time, and that port must be online and connected to a remote device. To run the online loopback test, do the following:

1.To start an admin session, enter the following command and press the Enter key.

admin start

2.To run the online loopback test, enter the following command and press the Enter key.

test x online

59021-05 A

B-67

Page 155
Image 155
Q-Logic B - Command Line Interface, Test Command, test x external, set port x state online, show port, 59021-05 A, B-67