Q-Logic manual B - Command Line Interface, Set Config Command, B-32, 59021-05 A

Models: 59021-05

1 180
Download 180 pages 45.41 Kb
Page 120
Image 120
B-32

B – Command Line Interface

 

 

￿

Set Config Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RisingTrigger

(decimal value, 1-1000)

[200

]

 

FallingTrigger

(decimal value, 0-1000)

[0 ]

 

 

SampleWindow

(decimal value, 1-1000 sec)

[10 ]

 

 

ISLMonitoringEnabled

(True / False)

[True]

RisingTrigger

(decimal value, 1-1000)

[2 ]

 

 

FallingTrigger

(decimal value, 0-1000)

[0 ]

 

 

SampleWindow

(decimal value, 1-1000 sec)

[10 ]

 

 

LoginMonitoringEnabled

(True / False)

[True]

RisingTrigger

(decimal value, 1-1000)

[5 ]

 

 

FallingTrigger

(decimal value, 0-1000)

[1 ]

 

 

SampleWindow

(decimal value, 1-1000 sec)

[10 ]

 

 

LogoutMonitoringEnabled

(True / False)

[True]

RisingTrigger

(decimal value, 1-1000)

[5 ]

 

 

FallingTrigger

(decimal value, 0-1000)

[1 ]

 

 

SampleWindow

(decimal value, 1-1000 sec)

[10 ]

 

 

LOSMonitoringEnabled

(True / False)

[True]

RisingTrigger

(decimal value, 1-1000)

[100 ]

 

FallingTrigger

(decimal value, 0-1000)

[5 ]

 

 

SampleWindow

(decimal value, 1-1000 sec)

[10

]

 

Finished configuring attributes.

 

 

 

This configuration must be saved (see config save command)

and activated (see

config activate command) before it can take effect. To discard this configuration use the config cancel command.config.