Table B-9. Set Config Threshold Parameters (Continued)

￿

 

B – Command Line Interface

 

Set Config Command

 

 

 

 

 

 

 

 

 

Table B-9. Set Config Threshold Parameters (Continued)

 

 

 

 

 

Parameter

 

Description

 

 

 

 

Rising Trigger

The event count above which a rising

 

 

threshold alarm is logged. The switch will

 

 

not generate another rising threshold

 

 

alarm for that event until the count

 

 

descends below the falling threshold and

 

 

again exceeds the rising threshold.

 

Falling Trigger

The event count below which a falling

 

 

threshold alarm is logged. The switch will

 

 

not generate another falling threshold

 

 

alarm for that event until the count

 

 

exceeds the rising threshold and

 

 

descends again below the falling

 

 

threshold.

 

Sample Window

The period of time in seconds in which to

 

 

count events.

 

 

 

 

zoning

Initiates an editing session in which to change switch zoning attributes. The system displays each parameter one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets.

Table B-10. Set Config Zoning Parameters

Parameter

Description

 

 

AutoSave

Enables (On) or disables (Off) the

 

saving of changes to active zone set in

 

the switch’s permanent memory.

 

Changes are always saved in the

 

switch’s temporary memory.

Default

Enables (All) or disables (None)

 

communication among the switch’s

 

ports/devices and the fabric in the

 

absence of an active zone set.

 

 