Appendix E

Connection to RS-422

E.1 General

Table E-1provides detailed information for connecting an ASM-20 (EIA 530) to a RS-422 (V.36) DTE.

Table E-1 Interface List for Connecting ASM-20 (RS- 530) to RS-422 (V.36) DTE

Signal Function

RS-449 (RS-422/423)

 

EIA 530

 

 

 

 

 

 

37 Pins

DB-25 Female Standalone

 

 

 

 

and Frame

 

Pin

Circuit

Pin

Circuit

 

 

 

 

 

Protective Ground

1

Shield

1

 

 

 

 

 

 

Signal Ground

19

SG

7

AB

 

 

 

 

 

DTE Common Return

37

SC

 

 

 

 

 

 

 

DCE Common Return

20

RC

 

 

 

 

 

 

 

Transmitted Data

4

SD (A)

2

BA (A)

 

22

SD (B)

14

BA (B)

 

 

 

 

 

Received Data

6

RD (A)

3

BB (A)

 

24

RD (B)

16

BB (B)

 

 

 

 

 

Request to Send

7

RS (A)

4

CA (A)

 

25

RS (B)

19

CA (B)

 

 

 

 

 

Clear to Send

9

CS (A)

5

CB (A)

 

27

CS (B)

13

CB (B)

 

 

 

 

 

Data Set Ready

11

DM (A)

6

CC (A)

 

29

DM (B)

22

CC (B)

 

 

 

 

 

Data Terminal Ready

12

TR (A)

20

CD (A)

 

30

TR (B)

23

CD (A)

 

 

 

 

 

Carrier Detect

13

RR (A)

8

CF (A)

 

31

RR (B)

10

CF (B)

 

 

 

 

 

External Transmit Clock

17

TT (A)

24

DA (A)

 

35

TT (B)

11

DA (B)

 

 

 

 

 

Transmit Clock

5

ST (A)

15

DB (A)

 

23

ST (B)

12

DB (B)

 

 

 

 

 

General E-1

Page 66
Image 66
RAD Data comm ASM-20 Appendix E Connection to RS-422, Signal Function RS-449 RS-422/423 EIA Pins, Pin Circuit