Chapter 1. Introduction

 

 

Digital Interface

Diagnostics

(Complies with the V.54 Standard)

Timing Elements

Type

V.24/RS-232 via 25-pin D-type, (up to 64 kbps

 

only), female connector

 

V.35 via 34-pin female connector

 

X.21 via 15-pin D-type female connector

 

RS-530 (RS-422) via 25-pin D-type female

 

connector

 

V.36 (RS-449) via 37-pin female connector

 

using mechanical cable adapter provided with

 

the product

 

G.703 Codirectional (64 kbps) via terminal

 

block or RJ-45

 

Built-in Ethernet bridge via RJ-45 connector or

 

BNC

Data Rates - selectable

Sync:

 

19.2, 32, 48, 56, 64, 72, 96, 112, 128, 144, 192,

 

256 kbps

 

Async:

 

19.2, 28.8, 38.4, 57.6, 115.2 kbps

RTS/CTS Delay

Switch selectable to:

 

- 0 ms

 

- 9 ms

 

- 70 ms

Length of Word

8, 9, 10, 11

Stop Bits

1, 1.5, 2

Digital Loopback

Local (DIG), activated by a manual switch

 

Remote (REM), activated by a manual switch

 

or by a control signal from the DTE interface

 

connector

Analog Loopback

Local (ANA), activated by a manual switch or by a

 

control signal from the DTE interface connector

Pattern

Test pattern activated by manual switch

Receive Clock

Derived from the receive signal

Transmit Clock

Derived from 3 alternative sources:

 

Internal oscillator

 

External from the DTE

 

Loop clock derived from the receive signal

Technical Specifications