Table 6-3 is a list of diagnostic messages that may be displayed on the

 

Integral Display, on the Model 275 HART Communicator or by the Radar

 

Configuration Tools (RCT) software. Warnings are less serious than errors

 

and in most cases do not result in Analog Output alarms.

 

Warnings are indicated by a message at the bottom of the RCT workspace. To

 

see the warning message do one of the following:

 

• Click the Read Gauge Status icon

in the toolbar at the top of the

 

RCT workspace.

 

 

• 1. Open the Advanced section in the RCT workspace Project Bar and

 

click the Device Commands icon,

 

 

or

 

 

choose the Device Commands option from the View menu.

 

2. Open the folder named Diag and double-click the Read Gauge

 

Status option.

 

Table 6-3. Warning messages.

 

 

 

 

 

Reference pulse not

Possible cause:

View the waveform plot and check

found.

Reference pulse immersed in

 

amplitude threshold T1.

 

 

high dielectric liquid.

Check that the tank is not overfull.

 

Wrong threshold level T1.

 

 

 

Hardware error.

 

 

 

 

 

 

No level pulse is

Possible cause:

 

 

found.

Wrong threshold level T2.

 

 

 

Liquid level in Dead Zone or

View the waveform plot and

 

 

below probe end.

 

check amplitude threshold T2.

 

 

 

 

Interface pulse not

Possible cause:

 

 

found.

Wrong threshold level T3.

 

 

 

Interface level too close to the

View the waveform plot and

 

 

upper product level.

 

check amplitude threshold T3.

 

No level pulse detected.

 

 

 

 

 

Internal temperature

-40 ºC<Internal Temperature<85 ºC.

Contact Rosemount service

out of range.

 

 

department.

 

 

 

 

 

Volume computation

Volume configuration error.

Check that correct tank type is

warning.

Strapping table error.

 

selected for volume configuration.

 

 

 

Check that tank dimensions for

 

 

 

 

volume are correct.

 

 

 

If strapping table is used, check the

 

 

 

 

level vs. volume points.

 

 

 

 

 

Immersed probe.

Wrong threshold level T4.

View the waveform plot and check

 

Reference pulse immersed in

 

amplitude threshold T4.

 

 

liquid.

 

 

 

 

 

 

 